We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical Products - Contactors & Starters For Sale | Exact Industrial Supply - (4027 Products)


Schneider Electric - Starter Control Unit - For Use with LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10


Item #: 56804719
Brand: Schneider Electric
Model #: LUCB1XB
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With LUFC00; LUFDA01; LUFDA10; LUFDH11; LUFN; LUFV2; LUFW10

$226.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 0-1, 12 to 18 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D18, LC1D25, LC1D32 and LC1D38


Item #: 69527380
Brand: Schneider Electric
Model #: LRD21L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 0-1
For Use With LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$86.12

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Control Unit - For Use with ASILUFC5, ASILUFC51, LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10, LULC031, LULC033, LULC07, LULC08, LULC09, LULC15


Item #: 56829518
Brand: Schneider Electric
Model #: LUCC1XBL
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With ASILUFC5; ASILUFC51; LUFC00; LUFDA01; LUFDA10; LUFDH11; LUFN; LUFV2; LUFW10; LULC031; LULC033; LULC07; LULC08; LULC09; LULC15

$226.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 48 to 80 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F115 and LC1F185


Item #: 56828890
Brand: Schneider Electric
Model #: LR9F5563
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F115; LC1F185
Voltage 1000 VAC
Maximum Overload (A) 80
Sensing Method Thermal
Minimum Overload (A) 48
Trip Class 20
Overall Height (mm) 96
Overall Width (mm) 123-1/2
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$445.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 80 to 104 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D80 and LC1D95


Item #: 69665180
Brand: Schneider Electric
Model #: LRD3365
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 104
Sensing Method Thermal
Minimum Overload (A) 80
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$175.12

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 75 Amp, 208 to 600 Coil VAC, 50/60 Hz, IEC Motor Starter - 1 Phase Hp: 20 at 208 Volt, 25 at 230 Volt, 3 Phase Hp: 50 at 460 Volt, 60 at 575 Volt


Item #: 69681054
Brand: Schneider Electric
Model #: ATS22D75S6U
Exact Tooling IR#: 04

Features and Benefits

Soft starters, also known as RVS (Reduced Voltage Starting), is generally used with large horsepower motors to reduce the inrush current and limit the torque output that can cause mechanical stress on the load.
Product Specifications
Starter Type Soft Starter
Amperage 75
Coil Voltage 208/600 VAC
Horsepower at 3 Phase 50 @ 460 V; 60 @ 575 V
Horsepower at 1 Phase 20 @ 208 V; 25 @ 230 V
Frequency Rating (Hz) 50/60
Overall Height (mm) 295
Overall Height (Decimal Inch) 11.6000
Overall Width (mm) 145
Overall Width (Decimal Inch) 5.7000
Overall Depth (mm) 247
Overall Depth (Decimal Inch) 9.7000
Standards Met B44.1-96/ASME A17.5; CCC; CE; CSA; C-Tick; EN/IEC 60947-4-2; GOST; IEC 61000-4-5 Level 3; RoHS Compliant; UL

$1,675.21

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 3 Pole, 110 VAC at 50 Hz, 120 VAC at 60 Hz and 600 Volt, 90 Continuous Amp, 1 hp, Open NEMA Combination Starter - ABS Type Approved, cUL Listed, NEMA ICS 2-1993, UL Listed


Item #: 02353175
Brand: Eaton Cutler-Hammer
Model #: CN15KN3A
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Single or three-phase refers to either a single coil or three individual coils that connect to and run voltage through the connector. Single-phase lines are used for light-to-medium operations and three-phase lines are used for medium-to-heavy operations.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 90
Starter Type NEMA
Enclosure Type Open
Compatible Motor Phase Single Phase, Three Phase
Action NonReversible
Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz; 600 V
Number of Poles 3
Horsepower (HP) 1
Overall Height (mm) 182.10
Overall Height (Decimal Inch) 7.1700
Overall Width (Decimal Inch) 4.0800
Overall Width (mm) 103.60
Overall Depth (mm) 150.90
Overall Depth (Decimal Inch) 5.9400
Standards Met ABS Type Approved; cUL Listed; NEMA ICS 2-1993; UL Listed

$2,546.88

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay - For Use with Motor Logic


Item #: 69651156
Brand: Square D
Model #: 9065ST220
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 2
For Use With Motor Logic
Voltage 600 VAC
Sensing Method Thermal

$310.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 24 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.3 at 120 VAC, 1 at 240 VAC, 3 Phase Hp: 2 at 208 VAC, 2 at 230 VAC, 5 at 460 VAC, 7.5 at 575 VAC


Item #: 49752108
Brand: Schneider Electric
Model #: LE1D093A62OB70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 9
Coil Voltage 24 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 2 @ 208 VAC; 2 @ 230 VAC; 5 @ 460 VAC; 7.5 @ 575 VAC
Horsepower at 1 Phase 0.3 @ 120 VAC; 1 @ 240 VAC
Enclosure Type Enclosed
Standards Met CSA; IEC; NEMA 1; UL

$191.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 62 Amp, 208 to 600 Coil VAC, 50/60 Hz, IEC Motor Starter - 1 Phase Hp: 15 at 208 Volt, 20 at 230 Volt, 3 Phase Hp: 40 at 460 Volt, 50 at 575 Volt


Item #: 69681062
Brand: Schneider Electric
Model #: ATS22D62S6U
Exact Tooling IR#: 04

Features and Benefits

Soft starters, also known as RVS (Reduced Voltage Starting), is generally used with large horsepower motors to reduce the inrush current and limit the torque output that can cause mechanical stress on the load.
Product Specifications
Starter Type Soft Starter
Amperage 62
Coil Voltage 208/600 VAC
Horsepower at 3 Phase 40 @ 460 V; 50 @ 575 V
Horsepower at 1 Phase 15 @ 208 V; 20 @ 230 V
Frequency Rating (Hz) 50/60
Overall Height (mm) 295
Overall Height (Decimal Inch) 11.6000
Overall Width (mm) 145
Overall Width (Decimal Inch) 5.7000
Overall Depth (mm) 247
Overall Depth (Decimal Inch) 9.7000
Standards Met B44.1-96/ASME A17.5; CCC; CE; CSA; C-Tick; EN/IEC 60947-4-2; GOST; IEC 61000-4-5 Level 3; RoHS Compliant; UL

$1,461.74

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Control Unit - For Use with ASILUFC5, ASILUFC51, LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10, LULC031, LULC033, LULC07, LULC08, LULC09, LULC15


Item #: 56829526
Brand: Schneider Electric
Model #: LUCD18BL
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With ASILUFC5; ASILUFC51; LUFC00; LUFDA01; LUFDA10; LUFDH11; LUFN; LUFV2; LUFW10; LULC031; LULC033; LULC07; LULC08; LULC09; LULC15

$226.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 23 to 32 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D25 and LC1D38


Item #: 54422795
Brand: Schneider Electric
Model #: LR3D32
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D25; LC1D38
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$102.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 37 to 50 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1D80 and LC1D95


Item #: 69648210
Brand: Schneider Electric
Model #: LR2D3557
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 50
Sensing Method Thermal
Minimum Overload (A) 37
Trip Class 20
Overall Height (mm) 100
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$149.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 VAC, 12 Continuous Amp, Enclosed IEC Combination Starter - NEMA 1


Item #: 56805096
Brand: Schneider Electric
Model #: LE1D126B62OG70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) starts are electrically controlled switches used to rapidly open (break) and close (make) a circuit. Similar to National Electrical Manufacturers' Association (NEMA) starters, IEC starters are much smaller and can provide quicker detection of overload conditions.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 12
Starter Type IEC
Enclosure Type Enclosed
Action NonReversible
Voltage 120 VAC
Standards Met NEMA 1

$876.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Auxiliary Contact - For Use with 100-400A Contactors


Item #: 02354181
Brand: Eaton Cutler-Hammer
Model #: C320KGS21
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Auxiliary Contact
For Use With 100-400A Contactors

$204.06

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 50 to 70 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 80-170 A Contactors


Item #: 08805418
Brand: Eaton Cutler-Hammer
Model #: XTOB070GC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 80-170 A Contactors
Voltage 690 VAC
Maximum Overload (A) 70
Sensing Method Thermal
Minimum Overload (A) 50
Trip Class 10
Overall Height (Decimal Inch) 5.4300
Overall Height (mm) 138
Overall Depth (mm) 134
Overall Depth (Decimal Inch) 5.2800
Overall Width (Decimal Inch) 4.6500
Overall Width (mm) 118
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$412.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 18 Amp, 240 Coil VAC at 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - Pushbutton Start (Green I), Pushbutton Stop/Reset (Red O)


Item #: 56804990
Brand: Schneider Electric
Model #: LE1D18U7
Exact Tooling IR#: 04

Features and Benefits

IEC contators without thermal overload relays may have fixed thermal elements that require replacing the complete overload relay. This may occur when significant motor full load current changes are due to application requirements.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Contactor without Thermal Overload Relay
Amperage 18
Coil Voltage 240 VAC @ 50/60 Hz
Action NonReversible
Motor Power 10 kW @ 500 VAC; 10 kW @ 660/690 VAC; 4 kW @ 220/230 VAC; 7.5 kW @ 380/400 VAC; 9 kW @ 415 VAC; 9 kW @ 440 VAC
Enclosure Type Enclosed
Operator Type Pushbutton Start (Green I); Pushbutton Stop/Reset (Red O)
Overall Height (mm) 201
Overall Width (mm) 101
Overall Depth (mm) 153
Standards Met AC-3; IEC 60529; IEC 60947-4-1; RoHS Compliant

$295.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 65 Amp, 208 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 10 at 230 Volt, 5 at 115 Volt, 3 Phase Hp: 20 at 200 Volt, 20 at 230 Volt, 40 at 460 Volt, 50 at 575 Volt


Item #: 56829377
Brand: Schneider Electric
Model #: LE1D653A62OL70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 65
Coil Voltage 208 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 20 @ 200 V; 20 @ 230 V; 40 @ 460 V; 50 @ 575 V
Horsepower at 1 Phase 10 @ 230 V; 5 @ 115 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 275
Overall Height (Decimal Inch) 10.8300
Overall Width (mm) 220
Overall Width (Decimal Inch) 8.6600
Overall Depth (mm) 183
Overall Depth (Decimal Inch) 7.2100
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$736.56

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 23 to 32 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 69648285
Brand: Schneider Electric
Model #: LRD332
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$148.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 3 Pole, NEMA Size 1, 2, 75 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 10 and 20, For Use with CE/CN Non-Reversing and Reversing Contactors


Item #: 02300804
Brand: Eaton Cutler-Hammer
Model #: C306GG3B
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 1; 2
For Use With CE/CN Non-Reversing & Reversing Contactors
Voltage 690 VAC
Maximum Overload (A) 75
Sensing Method Thermal
Trip Class 10; 20
Number of Poles 3
Standards Met CSA Certified; NEMA Compliant; UL 508 Single Phasing Requirements; UL Listed

$808.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It