We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical Products - Contactors & Starters For Sale | Exact Industrial Supply - (4027 Products)


Square D - NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay


Item #: 56812621
Brand: Square D
Model #: 9065SEO8S1
Exact Tooling IR#: 04

Product Specifications

NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay -
Starter Type NEMA
NEMA Size 2
Voltage 600 VAC
Sensing Method Thermal

$276.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 to 40 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 69648400
Brand: Schneider Electric
Model #: LR3D340
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 40
Sensing Method Thermal
Minimum Overload (A) 30
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$148.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 18 Amp, 208 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 1 at 115 Volt, 3 at 230 V Volt, 3 Phase Hp: 10 at 460 Volt, 15 at 575 Volt, 5 at 200 Volt, 5 at 230 VAC


Item #: 56829245
Brand: Schneider Electric
Model #: LE1D183A62OL70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 18
Coil Voltage 208 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 460 V; 15 @ 575 V; 5 @ 200 V; 5 @ 230 VAC
Horsepower at 1 Phase 1 @ 115 V; 3 @ 230 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 255
Overall Height (Decimal Inch) 10.0400
Overall Width (mm) 172
Overall Width (Decimal Inch) 6.7700
Overall Depth (mm) 158
Overall Depth (Decimal Inch) 6-1/4
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$287.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 9 to 12 Amp, 690 VAC, IEC Overload Relay - Trip Class 10


Item #: 08805509
Brand: Eaton Cutler-Hammer
Model #: XTOM012AC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
Voltage 690 VAC
Maximum Overload (A) 12
Minimum Overload (A) 9
Trip Class 10
Standards Met ATEX Compliant; CCC; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed; VDE 0660

$81.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 to 1.6 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D09 and LC1D38


Item #: 54422159
Brand: Schneider Electric
Model #: LR3D06
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D09; LC1D38
Voltage 690 VAC
Maximum Overload (A) 1.60
Sensing Method Thermal
Minimum Overload (A) 1
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$83.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Function Module - For Use with LUCB, LUCC, LUCD


Item #: 54523774
Brand: Schneider Electric
Model #: LUFDA01
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Function Module
For Use With LUCB; LUCC; LUCD

$183.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 0, 9 Amp, 600 VAC, Thermal NEMA Overload Relay - Trip Class 10 and 20, For Use with Square D Class 8536 Starters


Item #: 56812571
Brand: Square D
Model #: 9065ST022
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 0
For Use With Square D Class 8536 Starters
Voltage 600 VAC
Maximum Overload (A) 9
Sensing Method Thermal
Trip Class 10; 20

$510.34

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 1.6 Amp, IEC, Open Pushbutton Manual Motor Starter - 45mm Wide x 94mm Deep x 3.6667" High, 3/4 hp at 480/600 V, CE Approved, CSA Certified, DIN VDE, EN/IEC, UL 508 Type E Compliant & UL Listed


Item #: 08805764
Brand: Eaton Cutler-Hammer
Model #: XTPR1P6BC1
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) starts are electrically controlled switches used to rapidly open (break) and close (make) a circuit. Similar to National Electrical Manufacturers' Association (NEMA) starters, IEC starters are much smaller and can provide quicker detection of overload conditions.
Pushbutton switches are designed to turn electric on or off. It may consist of one or two contact blocks.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type IEC
Amperage 1.60
Operator Type Pushbutton
Enclosure Type Open
Horsepower (HP) 3/4 @ 480/600 V
Maximum Overload (A) 1.60
Minimum Overload (A) 1
Overall Height (mm) 93
Overall Height (Inch) 3.6667
Overall Height (Decimal Inch) 3.6600
Overall Width (mm) 45
Overall Width (Decimal Inch) 1.7700
Overall Depth (mm) 94
Overall Depth (Decimal Inch) 3.7000
Standards Met CE Approved; CSA Certified; DIN VDE; EN/IEC; UL 508 Type E Compliant; UL Listed

$228.45

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Pole, 600 VAC, 18 Continuous Amp, 3 hp and 5 hp hp, Enclosed NEMA Combination Starter - NEMA 1, RoHS Compliant


Item #: 69649853
Brand: Square D
Model #: 8538SBG11V02S
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Three-phase refers to three individual lines (coils) that connect to and run voltage through the motor. Each line alternates in a sequence as they reach their voltage peak. They provide a more stable flow of voltage and more horsepower to the equipment.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 18
Starter Type NEMA
Enclosure Type Enclosed
Compatible Motor Phase Three Phase
Action NonReversible
Voltage 600 VAC
Number of Poles 3
Horsepower (HP) 3; 5
Standards Met NEMA 1; RoHS Compliant

$1,533.45

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 90 to 150 Amp, 690 Volt, Thermal IEC Overload Relay - Trip Class 10 and 20, For Use with LC1D115, LC1D150 and NSX Circuit Breaker


Item #: 56829005
Brand: Schneider Electric
Model #: LR9D69
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D115; LC1D150; NSX Circuit Breaker
Voltage 690 V
Maximum Overload (A) 150
Sensing Method Thermal
Minimum Overload (A) 90
Trip Class 10; 20
Overall Width (mm) 132
Standards Met EN/IEC 60947-4-1; IEC 255-17; IEC 255-8; VDE 0660

$445.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Auxiliary Contact - For Use with 10-60A Contactors


Item #: 02354041
Brand: Eaton Cutler-Hammer
Model #: C320KGS4
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Auxiliary Contact
For Use With 10-60A Contactors

$129.26

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with MS Starters


Item #: 01260033
Brand: Eaton Cutler-Hammer
Model #: MSH14-2A
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With MS Starters

$67.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 208 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 1 at 230 Volt, 1/3 at 115 Volt, 3 Phase Hp: 2 at 200 Volt, 2 at 230 Volt, 5 at 460 Volt, 7.5 at 575 Volt


Item #: 49752090
Brand: Schneider Electric
Model #: LE1D093A62OL70
Exact Tooling IR#: 04

Features and Benefits

IEC contators without thermal overload relays may have fixed thermal elements that require replacing the complete overload relay. This may occur when significant motor full load current changes are due to application requirements.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Contactor without Thermal Overload Relay
Amperage 9
Coil Voltage 208 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 2 @ 200 V; 2 @ 230 V; 5 @ 460 V; 7.5 @ 575 V
Horsepower at 1 Phase 1 @ 230 V; 1/3 @ 115 V
Enclosure Type Enclosed
Frequency Rating (Hz) 50/60
Overall Height (mm) 99
Overall Height (Decimal Inch) 3.9000
Overall Width (mm) 90
Overall Width (Decimal Inch) 3.5400
Overall Depth (mm) 86
Overall Depth (Decimal Inch) 3.3800

$191.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 55 to 70 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1D80 and LC1D95


Item #: 69648194
Brand: Schneider Electric
Model #: LR2D3561
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 70
Sensing Method Thermal
Minimum Overload (A) 55
Trip Class 20
Overall Height (mm) 100
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$178.54

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Overload Relays Starter Type: IEC NEMA Size: 00-1


Item #: 55942148
Brand: Schneider Electric
Model #: LR9D08
Exact Tooling IR#: 04

Product Specifications

Overload Relays; Starter Type: IEC ; NEMA Size: 00-1 ; For Use With: LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38 ; Voltage: 690 V
Starter Type IEC
NEMA Size 00-1
For Use With LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 V

$130.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 440 Coil VAC at 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - Pushbutton Start (Green I), Pushbutton Stop/Reset (Red O)


Item #: 56805161
Brand: Schneider Electric
Model #: LE1D09R7
Exact Tooling IR#: 04

Features and Benefits

IEC contators without thermal overload relays may have fixed thermal elements that require replacing the complete overload relay. This may occur when significant motor full load current changes are due to application requirements.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Contactor without Thermal Overload Relay
Amperage 9
Coil Voltage 440 VAC @ 50/60 Hz
Action NonReversible
Motor Power 2.2 kW @ 220/230 VAC; 4 kW @ 380/400 VAC; 4 kW @ 415 VAC; 4 kW @ 440 VAC; 5.5 kW @ 500 VAC; 5.5 kW @ 660/690 VAC
Enclosure Type Enclosed
Operator Type Pushbutton Start (Green I); Pushbutton Stop/Reset (Red O)
Overall Height (mm) 166
Overall Width (mm) 88
Overall Depth (mm) 128
Standards Met AC-3; IEC 60529; IEC 60947-4-1; RoHS Compliant

$238.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 60 to 100 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F115 and LC1F185


Item #: 69527026
Brand: Schneider Electric
Model #: LR9F5567
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F115; LC1F185
Voltage 1000 VAC
Maximum Overload (A) 100
Sensing Method Thermal
Minimum Overload (A) 60
Trip Class 20
Overall Height (mm) 123-1/2
Overall Width (mm) 96
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$407.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 to 24 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D25 and LC1D38


Item #: 69527174
Brand: Schneider Electric
Model #: LR3D22
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D25; LC1D38
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$86.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2 Poles, 16 Amp, Open Toggle Manual Motor Starter - 1 hp at 115 VAC, 1 hp at 230 VAC, 1 hp at 277 VAC, 3/4 hp at 115 VDC & 3/4 hp at 230 VDC, CE, CSA & UL Listed


Item #: 56819568
Brand: Square D
Model #: 2510FF72P
Exact Tooling IR#: 04

Features and Benefits

Non-NEMA refers to the dimensions outside the parameters of the motor's dimensions within the standard NEMA designations for motor frame size
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type NonNEMA
Amperage 16
Operator Type Toggle
Enclosure Type Open
Horsepower (HP) 1 @ 115 VAC; 1 @ 230 VAC; 1 @ 277 VAC; 3/4 @ 115 VDC; 3/4 @ 230 VDC
Number of Poles 2
Standards Met CE; CSA; UL Listed

$407.28

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 17 to 25 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D80 and LC1D95


Item #: 69648160
Brand: Schneider Electric
Model #: LRD3322
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 25
Sensing Method Thermal
Minimum Overload (A) 17
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$148.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It